YE-RF-BT-A |
TACTILE TOUCH CONTROLLER PHONE W/ADAPTER
|
|
Y4E-CT-30-D |
TETHERED MONITOR OPERATOR STATION Same as above but the Tethered Control Station is supplied with a 30' (9m) long pre-connected cable.
|
|
|
A-DISP |
VALVE POSITION DISPLAY
|
|
Y4E-DISP |
MONITOR POSITION DISPLAY This display will show the stream position of any TFT RC electric monitor. Position is indicated by two sets of LEDs, one set for the vertical position and one set for the horizontal position. Buttons for the PARK & Oscillate features and HIGH/LOW speed selection are also supplied. A 10' (3m) long 4-conductor cable for power and communication is supplied pre-connected. When installed on systems w/RC Extend-A-Gun, the current state is indicated by LED (raised/lowered)
|
|
|
YE-RF-BT |
TACTILE TOUCH CONTROLLER PHONE ONLY
|
|
|
YC-RF-24 |
WIRELESS OPERATOR STATION 2.4 GHZ LONG DESCRIPTION
|
|
|
YC-RFRM-KIT |
ANTENNA & MONITOR MOUNTED O.S. KIT
|
|
|
YE-PWR-COND |
POWER CONDITIONER ADAPTER LONG DESCRIPTION
|
|
Y4E-JS |
JOYSTICK MONITOR OPERATOR STATION This operator station allows any TFT RC electric monitor to be controlled using a joystick. Moving the joystick controls monitor vertical and horizontal movement. Thumb switches control nozzle pattern. A trigger built into the joystick handle can be used to open and close some water valves. The joystick is factory installed on an enclosure that houses the control electronics and a 10' (3m) cable is supplied with stripped wires for connection in the control system terminal box. The joystick control is also equipped with push buttons on top for PARK and OSCILLATE functions as well as monitor DEPLOY. An additional configurable button can be set up for RC Extend-A-Gun or LED light kit control. A toggle switch is available to select water valve open, close, or joystick control. The joystick control can be configured for proportional speed control of the horizontal and vertical axis. The joystick control is factory wired so that the AUX2 button on TFT monitor operator stations will also open and close the water valve. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel.
|
|
|
YE-ABS-POS-1 |
ABSOLUTE POSITION UPGRADE KIT
|
|
|
YC-RP |
PANEL MOUNTED OPERATOR STATION LONG DESCRIPTION
|
|
YE-REMAUX |
REMOTE AUXILIARY FUNCTION RELAY INTERFACE BOX This interface box allows a user to utilize the AUX1 and AUX2 buttons located on the monitor operator station, any remote operator station with a membrane switch or inputs located in part #Y4E-COMM. The interface box is equipped with two relays that can operate lights, interface to a valve controller or in some cases operate a valve directly, etc. The contact rating of the relay is 16 amps @ 30VDC for resistive loads and 8 amps @ 30VDC for inductive loads. A 10' (3m) long 4-conductor cable for power and communication is supplied pre-connected.
|
|
|
YC-CT-30 |
TETHERED OPERATOR STATION LONG DESCRIPTION
|
|
YE-RF-900 |
WIRELESS MONITOR OPERATOR STATION, 900 MHz This operator station allows one RC monitor to be controlled using a wireless handheld transmitter. The wireless transmitter will operate up to 500' (152m) away from the truck. This operator station is supplied with a stainless steel mounting bracket to securely store the handheld unit. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel. See RC monitor installation & operation manual for operating frequency agency approvals or consult factory for agencies not listed. Order one radio & antenna for each RC monitor, listed below.
|
|
|
YE-ETH-WIFI |
ETHERNET INTERFACE CONTROL FOR WIRED NETWORKS Same as above except for use with standard wireless Ethernet networks. Contact factory for configuration assistance.
|
|
|
|
Y4E-CT-10 |
TETHERED MONITOR OPERATOR STATION This operator station allows the electric monitor to be controlled from a handheld pendant. This operator station is supplied with a stainless steel mounting bracket to securely store the unit. The enclosure has an O-ring seal, liquid tight strain relief fitting with O-rings, and a membrane switch to keep water out. Any commands from this operator station will override commands made on the monitor control box. The pendant receptacle can be connected to the Panel Mount Operator Station or directly to the monitor through a customer supplied terminal block. A cable is supplied pre-connected to the panel-mounted receptacle and includes waterproof cap and chain. The Tethered Control Station is supplied with a 10' long pre-connected cable. This pendant plugs into a panel-mounted receptacle. This operator station is equipped with "last button pressed" software or can be configured as a "master" station. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel.
|
|
|
YE-RF-BT-I |
TACTILE TOUCH CONTROLLER PHONE ONLY
|
|
|
YE-CAN1 |
MULTIPLEX INTERFACE
|
|
|
YE-CAN2 |
MULTIPLEX ADAPTER SMALL PACKAGE
|
|
|
YE-RF-BT |
TACTILE TOUCH CONTROLLER PHONE ONLY
|
|
YE-RECEP-4 |
PANEL MOUNTED RECEPTACLE This receptacle allows tethered monitor operator stations to be connected at additional locations. A 30' (9m) long cable with a pre-connected receptacle is supplied. Includes waterproof cap and chain.
|
|
|
Y4E-CT-100-D |
TETHERED MONITOR OPERATOR STATION Same as above but the Tethered Control Station is supplied with a 100' (30m) long pre-connected cable.
|
|
Y4E-TS |
TOGGLE SWITCH MONITOR OPERATOR STATION This operator station allows any TFT RC electric monitor to be controlled using three toggle switches. Switches control monitor vertical and horizontal movement plus nozzle pattern adjustment. The operator station can be surface mounted. A 10' (3m) long 4-conductor cable for power and communication is supplied pre-connected. This operator station is equipped with "last button pressed" software or can be configured as a "master" station.
|
|
|
YC-RF-24 |
WIRELESS OPERATOR STATION 2.4 GHZ LONG DESCRIPTION
|
|
|
YC-RP |
PANEL MOUNTED OPERATOR STATION LONG DESCRIPTION
|
|
|
YC-RFRM-KIT |
ANTENNA & MONITOR MOUNTED O.S. KIT
|
|
YE-REMAUX |
REMOTE AUXILIARY FUNCTION RELAY INTERFACE BOX This interface box allows a user to utilize the AUX1 and AUX2 buttons located on the monitor operator station, any remote operator station with a membrane switch or inputs located in part #Y4E-COMM. The interface box is equipped with two relays that can operate lights, interface to a valve controller or in some cases operate a valve directly, etc. The contact rating of the relay is 16 amps @ 30VDC for resistive loads and 8 amps @ 30VDC for inductive loads. A 10' (3m) long 4-conductor cable for power and communication is supplied pre-connected.
|
|
|
YE-PWR-COND |
POWER CONDITIONER ADAPTER LONG DESCRIPTION
|
|
|
YC-CT-30 |
TETHERED OPERATOR STATION LONG DESCRIPTION
|
|
YE-RF-900 |
WIRELESS MONITOR OPERATOR STATION, 900 MHz This operator station allows one RC monitor to be controlled using a wireless handheld transmitter. The wireless transmitter will operate up to 500' (152m) away from the truck. This operator station is supplied with a stainless steel mounting bracket to securely store the handheld unit. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel. See RC monitor installation & operation manual for operating frequency agency approvals or consult factory for agencies not listed. Order one radio & antenna for each RC monitor, listed below.
|
|
|
|
YE-RECEP-4 |
PANEL MOUNTED RECEPTACLE This receptacle allows tethered monitor operator stations to be connected at additional locations. A 30' (9m) long cable with a pre-connected receptacle is supplied. Includes waterproof cap and chain.
|
|
|
Y4E-CT-100-D |
TETHERED MONITOR OPERATOR STATION Same as above but the Tethered Control Station is supplied with a 100' (30m) long pre-connected cable.
|
|
Y4E-JS |
JOYSTICK MONITOR OPERATOR STATION This operator station allows any TFT RC electric monitor to be controlled using a joystick. Moving the joystick controls monitor vertical and horizontal movement. Thumb switches control nozzle pattern. A trigger built into the joystick handle can be used to open and close some water valves. The joystick is factory installed on an enclosure that houses the control electronics and a 10' (3m) cable is supplied with stripped wires for connection in the control system terminal box. The joystick control is also equipped with push buttons on top for PARK and OSCILLATE functions as well as monitor DEPLOY. An additional configurable button can be set up for RC Extend-A-Gun or LED light kit control. A toggle switch is available to select water valve open, close, or joystick control. The joystick control can be configured for proportional speed control of the horizontal and vertical axis. The joystick control is factory wired so that the AUX2 button on TFT monitor operator stations will also open and close the water valve. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel.
|
|
Y4E-TS |
TOGGLE SWITCH MONITOR OPERATOR STATION This operator station allows any TFT RC electric monitor to be controlled using three toggle switches. Switches control monitor vertical and horizontal movement plus nozzle pattern adjustment. The operator station can be surface mounted. A 10' (3m) long 4-conductor cable for power and communication is supplied pre-connected. This operator station is equipped with "last button pressed" software or can be configured as a "master" station.
|
|
|
YE-ETH-WIFI |
ETHERNET INTERFACE CONTROL FOR WIRED NETWORKS Same as above except for use with standard wireless Ethernet networks. Contact factory for configuration assistance.
|
|
Y4E-JS-GT-R |
JOYSTICK OPERATOR STATION
|
|
|
YE-ETHER |
ETHERNET INTERFACE CONTROL FOR WIRED NETWORKS This interface box enables a TFT RC monitor to be connected and controlled via a standard wired Ethernet network. This unit is designed to be operated from a PC or tablet running a standard web browser. The interface acts as a web server and no custom software is required. The interface box includes a pre-wired 10' (3m) cable with receptacle for monitor connections and a 10' (3m) cable for power connections and communication connections to other remote accessories (if any).
|
|
Y4E-RP |
PANEL MOUNT MONITOR OPERATOR STATION This operator station allows the electric monitor to be controlled from a remote location and is designed to be flush mounted in a panel. This station may be used as the central location for terminating the wires from the monitor, incoming power, or hard wired inputs. All terminal blocks for wire connections are removable for easy terminating. The enclosure has an o-ring seal, liquid tight strain relief fittings with o-rings, and a membrane switch to keep water out. A 30' long cable for incoming power and communication connections is supplied pre-connected. This operator station is equipped with "last button pressed" software or can be configured as a "master" station.
|
|
|
YE-1F2M |
MONITOR CONNECTION HARNESS
|
|
|
YE-BT1 |
BLUETOOTH ADAPTER SMALL PACKAGE
|
|
|
YE-VK-PD |
VALVE KIT 1" NPT
|
|
|
YE-CAB-6 |
EXTENSION CABLE 4 CONDUCTOR
|
|
|
YE-RF-920-D |
WIRELESS OPERATOR STATION WITH DISPLAY
|
|
Y4E-JS-52 |
JOYSTICK MONITOR OPERATOR STATION Same as above except cable has plug to connect to YE-VK valve interface box receptacle (not included).
|
|
|
Y4E-JS-LT |
JOYSTICK OPERATOR STATION LT VERSION
|
|
|
|
|
YE-RF-RAD-92 |
WIRELESS RADIO AND ANTENNA 920 MHZ
|
|
|
YE-RF-2400-D |
WIRELESS OPERATOR STATION WITH DISPLAY
|
|
Y4E-JS-52 |
JOYSTICK MONITOR OPERATOR STATION Same as above except cable has plug to connect to YE-VK valve interface box receptacle (not included).
|
|
|
YC-RF-24 |
WIRELESS OPERATOR STATION 2.4 GHZ LONG DESCRIPTION
|
|
|
YE-CAB-6 |
EXTENSION CABLE 4 CONDUCTOR
|
|
|
YE-1F3M |
MONITOR & VUM CONNECTION HARNESS
|
|
|
YC-RFRM-KIT |
ANTENNA & MONITOR MOUNTED O.S. KIT
|
|
|
YE-PWR-COND |
POWER CONDITIONER ADAPTER LONG DESCRIPTION
|
|
YE-LK24-KIT |
LED SEARCH LIGHT KIT W/ BRACKET
|
|
|
YE-ETH-PLC |
ETHERNET INTERFACE CONTROL FOR WIRED NETWORKS This interface box enables a TFT RC monitor to be connected and controlled via an industrial type programmable logic controller (PLC). Contact customer service for list of compatible PLCs. Same cabling supplied as units above.
|
|
|
YE-ABS-POS-1 |
ABSOLUTE POSITION UPGRADE KIT
|
|
|
YE-RF-BT-I-A |
TACTILE TOUCH CONTROLLER PHONE W/ADAPTER
|
|
|
YC-RP-01 |
PANEL MOUNTED OP STATION FOR AERIALS
|
|
YE-RF-900-D |
WIRELESS MONITOR OPERATOR STATION WITH DISPLAY, 900 MHz Allows RC monitors to be controlled using a wireless handheld transmitter. The unit is easily configurable for multi-monitor control. This will allow a user to control up to ten TFT RC monitors from one operator station. The wireless transmitter will operate up to 500' (152m)away from the truck and is supplied with a stainless steel mounting bracket to securely store the handheld unit. This operator station includes a display for advanced system feedback and a backlit control panel for improved visibility of controls in low-light conditions. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel. See RC monitor installation & operation manual for operating frequency agency approvals or consult factory for agencies not listed. Order one radio & antenna for each RC monitor, listed below.
|
|
|
YE-VKG-PD |
GATEABLE VALVE KIT This valve kit includes a heavy-duty 1" NPT (25mm) water valve and an interface box for simplified 12/24 volt wire connections to the monitor control system. The valve is a 1" NPT (25mm) full port stainless steel ball valve with integral electric actuator control with valve opening position sensing and cable with pre-wired plug.
|
|
|
|
Y4E-RP |
PANEL MOUNT MONITOR OPERATOR STATION This operator station allows the electric monitor to be controlled from a remote location and is designed to be flush mounted in a panel. This station may be used as the central location for terminating the wires from the monitor, incoming power, or hard wired inputs. All terminal blocks for wire connections are removable for easy terminating. The enclosure has an o-ring seal, liquid tight strain relief fittings with o-rings, and a membrane switch to keep water out. A 30' long cable for incoming power and communication connections is supplied pre-connected. This operator station is equipped with "last button pressed" software or can be configured as a "master" station.
|
|
|
YE-ETHER |
ETHERNET INTERFACE CONTROL FOR WIRED NETWORKS This interface box enables a TFT RC monitor to be connected and controlled via a standard wired Ethernet network. This unit is designed to be operated from a PC or tablet running a standard web browser. The interface acts as a web server and no custom software is required. The interface box includes a pre-wired 10' (3m) cable with receptacle for monitor connections and a 10' (3m) cable for power connections and communication connections to other remote accessories (if any).
|
|
|
YE-1F2M |
MONITOR CONNECTION HARNESS
|
|
|
YE-BT1 |
BLUETOOTH ADAPTER SMALL PACKAGE
|
|
|
YE-CAB-6 |
EXTENSION CABLE 4 CONDUCTOR
|
|
Y4E-JS |
JOYSTICK MONITOR OPERATOR STATION This operator station allows any TFT RC electric monitor to be controlled using a joystick. Moving the joystick controls monitor vertical and horizontal movement. Thumb switches control nozzle pattern. A trigger built into the joystick handle can be used to open and close some water valves. The joystick is factory installed on an enclosure that houses the control electronics and a 10' (3m) cable is supplied with stripped wires for connection in the control system terminal box. The joystick control is also equipped with push buttons on top for PARK and OSCILLATE functions as well as monitor DEPLOY. An additional configurable button can be set up for RC Extend-A-Gun or LED light kit control. A toggle switch is available to select water valve open, close, or joystick control. The joystick control can be configured for proportional speed control of the horizontal and vertical axis. The joystick control is factory wired so that the AUX2 button on TFT monitor operator stations will also open and close the water valve. Mounting bracket meets NFPA 1900 9G force requirements which ensures the security of equipment and safety of personnel.
|
|
|
YE-ETH-WIFI |
ETHERNET INTERFACE CONTROL FOR WIRED NETWORKS Same as above except for use with standard wireless Ethernet networks. Contact factory for configuration assistance.
|
|
Y4E-JS-GT-R |
JOYSTICK OPERATOR STATION
|
|
|